Registration Number 011-7S1889 R

Certificate / Registration Holder:
Ritter Energie- und Umwelttechnik
GmbH & Co. KG
Kuchenäcker 2
72135 Dettenhausen
Germany

Phone: +49 7157 53591200-1200
Fax: +49 7157 53591209-1209
Email: info@ritter-energie.de
Internet: www.ritter-energie.de
Ritter Energie- und Umwelttechnik
Product: Solar collectors
Type / Model:

AQUA PLASMA 15/27, AQUA PLASMA 15/40, AQUA PLASMA 19/17,
AQUA PLASMA 19/34, AQUA PLASMA 19/50

Testing Basis: Specific CEN Keymark Scheme Rules for Solar Thermal Products Version 29.00 (as of 2016-12)
DIN EN 12975-2:2006-06
DIN EN ISO 9806:2014-03
DIN EN 12975-1:2011-01
Mark of Conformity: Quality mark KEYMARK / DIN-Geprüft
Registration Number: 011-7S1889 R
Valid until: 2022-05-31
Technical Data:

See data sheet, part of the test report of 2012-05-29, 2014-06-05

Note(s):

- The freeze resistance test according to DIN EN 12975-2, clause 5.8 was
not necessary. According to the manufacturer's declaration, the
certified solar collectors may be used in frost exposed areas only in
combination with appopriate frost protection mixtures or with
appropriate frost protection controller.

The reliability tests have been performed according to DIN EN 12975-2
besides the impact resistance test. This test has been performed
according to DIN EN ISO 9806.

Document: Info(PDF)